Setting the V5.2 protocol over E1

Assume an SS7 - V5.2 protocol conversion application with using a Stillink 800 (ordering code s80.4s4v000). To begin with, set E1-00, E1-01, E1-02, and E1-03 interfaces to CCITT signaling type no:7 ISUP and select the Digital trunks for synchronization. Adjust SS7 signaling parameters. Monitor the SS7 E1 interface (especially the one having the signaling channel D) and be sure about the communication there. Then, store the parameters into the non-volatile memories. Refer to General Topics for these programming.

Then, E1-04, E1-05, E1-06, and E1-07 should be set to V5.2 LE . In this Stillink system:

  • All four E1s can be bundled into a single V5.2 interface. That is a single V5.2 interface having four E1 links, which are E1-04, E1-05, E1-06, and E1-07.
  • Independent V5.2 interfaces can be created such as:
  • Two V5.2 interfaces, each with 2 E1 links (total number of E1s equals to four), or
  • Four V5.2 interfaces, each with a single E1 link (total number of E1s again equals to four), or
  • Some other configurations.

However, the most frequent application is a conversion from a single V5.2 LE interface to the SS7. So as to bundle E1-04, E1-05, E1-06, and E1-07 into a single V5.2 interface, do the following:

Step-1

  • In Homepage, click on Users/Find item.
  • Select to edit page is displayed.
  • For E1-04, edit 50400 into the textbox .
  • Click on Common button. Common properties page is displayed
  • Change interface type to E1 ETSI V5.2 Local Exchange LE
  • Click on Apply button.
  • Common properties page will refresh and become a simple one.
  • Repeat the same for E1-05 (50500), E1-06 (50600), and E1-07 (50700).

Tips

For each V5.2 signaling E1, the V5.2 Interface name (shown in Common Properties page) is 0 by default. This name is only used during programming a Stillink system. This name is not used in any messages of the V5.2 protocol. In programming, the E1s sharing the same interface name are in the same V5.2 interface. In order to check, access to the Common Properties page for E1-04, E1-05, E1-06, and E1-07, see that V5.2 Interface name is set to 0 for each of them. Do not modify this number, keep it.

Step-2

  • In Homepage click on V5.2 Interface item .
  • Select to edit page is displayed
  • Select LE 0 and then click on OK button.
  • V5.2 interface properties page for the LE 00 is displayed.

In this page, set the interface parameters in order to match similar parameters in the AN side. The adjustable parameters are:

  • Primary link (E1-04, E1-05, E1-06, or E1-07)
  • Secondary link (E1-04, E1-05, E1-06, or E1-07)
  • Protection Ptcl logical c channel
  • Links ( for Link IDs of E1-04, E1-05, E1-06, and E1-07
  • Page links for PSTN and ISDN users
  • Variant number
  • Logical address
  • Call priority
  • PSTN cadence
  • Click on OK button after adjusting the parameters.

Step-3

  • Store the programmed parameters to non-volatile memories with using Save command in Homepage
  • Reset the system with using Control Program - Reboot command in Homepage
  • After the restart, monitor the primary and secondary links to see the links are up

Adding V5.2 PSTN or BRI ISDN users

After setting the V5.2 interface up and seeing the communication on the primary and secondary links, PSTN and/or BRI ISDN users can be added for the interface.

Go with the above mentioned example. An SS7 - V5.2 protocol conversion application with using a Stillink 800 (ordering code s80.4s4v000). E1-00, E1-01, E1-02, and E1-03 are set to CCITT signaling type no:7 ISUP . E1-04, E1-05, E1-06, and E1-07 are bundled into the V5.2 LE 00 interface.

To add a PSTN user, do the following:

  • Go to V5.2 interface properties page for the LE 00.
  • Click on Pstn Users item.
  • V5.2 Users page is displayed.
  • Click on the Add button.
  • V5.2 users page will refresh with a new user.
  • Repeat this operation to add any number of PSTN users. The Stillink will assign access codes for users automatically

The result is several PSTN users in V5.2 Interface Users LE 00 Pstn page. In this page, for each PSTN user, there are two fields;

  • access code field (like 1498, 1499, 1500, 1501....), and
  • port ID or EF address field (by default, it is 0 for all access codes). EF address of the port as ETSI EN 300 347. This address will be used by both AN and LE side while referencing to this user. Valid values are 1-16383. If address is set to 0, provisioning of the user with the peer will not be performed (ie. user will not be available).

In order to change the port ID or EF address, select a user by marking it and then click on Edit button.

In Common properties page of the Pstn user, edit the EFadr field accordingly

  • Click on OK button.
  • Change the port ID or EF addresses of other users in their Common properties pages.

Next step is to activate the added PSTN users. This can be done by restarting the Stillink or the AN equipment, or by disconnecting and connecting again the physical E1 wire (connector) in front of the Stillink system for the primary and secondary links.

Setting the routing parameters

Consider the Stillink 800 programmed above. Assume that 100 PSTN users have been defined in this Stillink. The PSTN user access codes are from 1500 to 1599, and these access codes have the Port Ids (EF addresses) programmed according to the connected AN. Assume EF addresses from 100 to 199 in sequence. Let the requirement to be the following:

  • All physical PSTN users in the AN side should be transparently routed to the SS7 network. The dialed numbers may be minimum 3 digit and maximum 20 digit long.
  • From the SS7 network, called party addresses to be received are from 4448600 to 4448699. The called party address from 4448600 to 4448699 should ring on the AN subscribers with Port IDs 100 to 199 respectively.

Do this programming as follows:

Step-1

Program all SS7 interfaces (E1-00, E1-01, E1-02, E1-03) such that

  • Their routing tables are set to 10, and their route numbers are set to 10 for all of their voice channels (see General Topics section about how to achieve this).
  • Program the Routing criteria table 10 such that Prefix field has 44486, Min field has 7, Max field has 7, Replacement digits field has 15fg , Law action field has Subscriber access code, Required authorization fields have 0.

WHAT IS DONE for Routing criteria table 10? If any call with the called party address number like 44486XX is received from the SS7 network, this call will be routed to the Subscriber access code with some digit replacement such that:

  • the first 5 digits will be deleted, that is 44486
  • 15 will be added in the front
  • the other digits will be kept
  • consequently, 44486XX will be replaced to 15XX
  • Note that 15XX refers to the EF address 1XX

Step-2

Program the routing table of the V5.2 PSTN users. Do the following:

  • Open the Common properties page for the user 1500
  • Assign a Routing criteria table. Assume that 11 is assigned.
  • Click on the OK button.
  • Repeat the same, i.e., assignment of Routing table 11 for the other access codes 1501 to 1599.

Tips

After selecting the Routing table 11 for the access code 1500, this parameter can be copied onto the other access codes (1501 to 1599) with a simple command. This will make the programming easy and short. To do this select Copy-Users item in Homepage.

Copy page is displayed. In this page, select 1500 as the Source and 1501 to 1599 as the Destination and then click on OK button.

It is possible to adjust several parameters of the V5.2 users such as CLIP, Charge Pulse, and Credit. Some of these parameter adjustments can be done in Common properties, but most of these can be done in User properties pages. Both common and user properties can be accessed with using Users item in Homepage.

Next is to program the Routing criteria table 11 such that

  • 10 rows
  • Prefixes single digit from 0 to 9
  • Min is 3 for all prefixes
  • Max is 31 for all prefixes
  • Number of used Law is 165

Law action as R10 (route 10)

To illustrate, for the Prefix 2, the Routing criteria will look like below:

At the end of programming, the Routing criteria table 11 will look like below.

WHAT IS DONE for routing table 11? If any call with any called party address (minimum 3 digit and maximum 31 digit long) is received from a V5.2 user, this call will be routed to the Port Route 10 that is SS7 network. Remember that all SS7 signaling E1 have been in Port Route 10.

Tips The Stillink will route the call of a V5.2 user immediately after the receipt of Max number of digits or the time-out occurrence. The default value of this timer is 8 seconds. This timer may be changed, however it is not recommended to make it less than 4 seconds. To change the timer, Edit the Signaling table of the V5.2 user. The Signaling table can be accessed in Common properties page.

  • By default, Table 0 is assigned to all users, click on the Edit button.
  • The relevant timer in this page is Ic. Interdigit timer By default, it is 80, which indicates 8 seconds.
  • Edit the new value and click on the OK button..

Step-3

  • Store the programmed parameter to non-volatile memories with using Save command in Homepage..

Tips

Before storing the programmed parameters, be sure that all the programming done is correct and according to the requirements. So that, it is recommended to create some test calls from SS7 network to the V5.2 LE, and vice versa.

Print - Recent Changes - Search
Page last modified on February 23, 2011, at 07:01 AM EST
Subject to change without any notice. All rights reserved 2010 - Telesis A.S.
Iskitler Cad. No.68 Ankara, TURKEY. Tel: +90 312 3840540 Fax: +90 312 3840549 http://www.telesis-pbx.com