Recent Changes - Search:

Resources


IP PBX Systems


Telephony Switch


Phones


Access Gateway
Signaling Converter


Lawful Interception Recorder


Others


Discontinued Products


Main Domains


In Social Media


About Us
Contact Details





.

Some_Routing_Law_Actions_In_Xymphony

Routes R0 to R127
Replacement digits are transmitted out from the selected route as the new called-party number.

Port access code
Call is routed to the port with the access code matching the replaced digits.

Subscriber access code
Call is routed to the subscriber with the access code matching replaced digits.

Trunk access code
Call is routed to the trunk with the access code matching replaced digits.

Single port routing
Call is routed to a port with the access code matching to the authorized users Single port routing field in Common properties.

Test tone
Test tone towards the calling (incoming) user regardless of replacement digits

Vacant tone
Vacant tone towards the calling (incoming) user regardless of replacement digits

Overflow tone
Overflow tone towards the calling (incoming) user regardless of replacement digits

Parameter store
Similar to the Save command. Operational parameters from RAM are stored into the non-volatile memories of the system. Prefer, web server pages to store parameters.

Call forwarding unconditional
Forwarding digits should follow. Upon receiving # or going on hook, update performed. All calls to the user are forwarded using the following digits.

Call forwarding busy
Forwarding digits should follow. Upon receiving # or going on hook, update performed. Whenever the user is unavailable, all calls to the user are forwarded using the following digits.

Call forwarding no reply
Forwarding digits should follow. Upon receiving # or going on hook, update performed. Upon alerting timeout, received call is forwarded using the following digits.

Delayed hot line
Hot line digits should follow. Upon receiving # or going on hook, update performed. Whenever the user goes off hook, delayed hot line timer (Adjustable in Signaling table) is set. Upon expiry of the timer, call is setup using the following digits.

Password login
Access code (1-8 digits) and password (4 digits) of the user should follow. After logging in, ack tone will be received. Further received digits will be processed using the new user account.

Password update
Access code (1-8 digits), current password (4 digits) and requested password (4 digits) should follow.

Call pickup
Access code of the alerted port should follow. If no digit dialed and user is defined as in route, all users in same route is scanned to pick up the call.

Routed call pickup
If the user is defined as in route, all users in same route is scanned to pick up the call. If no suitable call is fount to pickup, highest priority call in queue is answered.

Call pickup by route
3 digit route number should follow. All users of that route is scanned to pick up the call.

Call suspend
If a held call exists, it is suspended. After the user goes on hook, suspended call survives to be resumed

Call resume
Access code of the suspended or suspending call should follow.

Voice message recording
2 digit System message no should follow.

Voice message play
1 digit play type and 2 digit System message number should follow. If play type is 0, DTMF reception is enabled and routing analysis restarted. If play type is 1, DTMF reception is not permitted.

Vmail record
If Voice message quota in User properties is not empty, recording performed.

Vmail play
If the user has a password defined, 4 password digits to be dialed after the function code.

Personal greeting
Dialing 0 removes the personal greeting message, 1 records new message. If recorded message exists, this message played to users Vmail recording to this account.

Night restriction setting
Following 0 clears, 1 sets system night restriction,

User Pool Update
1-9 should follow as the address of the user speed dial memory address, *, # or going on hook, performs the update.

Dial from user pool
1-9 should follow as the address of the user speed dial memory address.

Dial from common pool
000 to 999 should follow as the common pool memory address.

Reminder service activation
4 digits as HHMM should follow. Until deactivation, user is alerted every day.

Reminder activation (temporary)
4 digits as HHMM should follow. User is alerted once.

Reminder sequence
4 digits as HHMM should follow. Access code of the user to activate reminder service (temporary) can be entered. Multiple access codes permitted. Suitable for Hotel guest group reminder requests.

Do not disturb activation
Until deactivation, user will not receive calls.

Call back
Following 0 deactivates callback, 1 activates callback busy or call back no answer if the user hook flashed upon receiving busy or ringback tone.

DC loop trunk tests
For factory tests.

Reject diverted calls activation
If activated, diverted calls are not accepted

Override diversions (default 823)
If the called party activated call forwarding feature, it is over-rided. Actual called party is alerted.

Call intrusion
Access code of the user to be intruded should follow, and it should be engaged in a call. Intrusion authorization of the intruding user should be higher then both of the intruded users.

Forced release
If the called party is engaged in an active or progressing call, it is released.

Divert routed calls
Applicable to users defined in a route. All calls to the route are forwarded using the following digits.

Divert all calls
Functions of Divert routed calls and Call forwarding unconditional performed.

Message waiting
Access code of the user to set message waiting should follow. Requested user alerted periodically and if the hardware is suitable message waiting visual indicator flashed. Upon seizure of the requested party, requesting user called.

Trunk to trunk tests
For factory tests.

Credit adding
Access code of the user and 4 digit credit should follow.

User authorizations sf.
4 password digits and 2 call class digits to be dialed after the function code. Valid call classes are 00-15 and 99 interpreted as all call classes. Following 0 disables, 1 enables authorization. If the user do not have a password, function fails.

Room house keeping
Following 0 resets as clean, 1 as to be cleaned.

Room report
2 digit item no and 2 digit quantity should follow.

Room occupancy
For Hotel guest rooms, Following 0 sets to vacant, 1 to reserved, 2 to occupied, 3 to unavailable. Access code should follow occupancy state.

Room query
House keeping, occupancy , reminder time, credit, do not disturb and message waiting statuses displayed on digital sets.

SLIC Tests
For factory tests.

Campon to subscriber
System periodically scans the called subscribers availability to setup the call. Call forwarding of the called user is overrided.

Auto attendant
Auto attendant id. (2 digits) to serve the call setup should follow.

XID key
FOR FACTORY SET UP AND TESTING. NEVER USE THIS LAW ACTION!.

Multi station call
2 digit table number to be dialed. All users defined in the table will be alerted. First connect message from one of these users will release the rest of the calls.

Auto dialing
Following 0 removes active request, 1 puts last dialed number to queue, 2 queries active request. To use this feature on analog DC loop trunks, call progress detection frequencies should be set. (System/Basic/Auto dialer)

Conference room
Unlimited number of users can enter the conference room. Ring down tie trunks can not participate as no clearing signal is defined. DC lop trunks can participate but all participants can not be DC loop trunks. In such a case all will be cleared. While conferencing, DC loop trunks are monitored to detect overflow tone to remove them from the conference room. To have this detection System/Basic/Auto dialer frequencies should be set.

Multi station conference
2 digit table number to be dialed. Calling party directly enters the conference room. All users defined in the table will be alerted. Answering users will enter the conference room.

Multi station voice msg.
2 digit table number and 2 digit system voice message no to be dialed. All users defined in the table will be alerted. Answering users will receive the requested system message.

Digital set tests
For factory testing of digital sets, not to be used during normal operation.

Print - Recent Changes - Search
Page last modified on November 18, 2015, at 09:14 AM EST
Subject to change without any notice. All rights reserved 2010 - Telesis A.S.
Iskitler Cad. No.68 Ankara, TURKEY. Tel: +90 312 3840540 Fax: +90 312 3840549 http://www.telesis-pbx.com